⚑ BEE Certified Energy AuditorπŸ”© Chartered Engineer (IEI)πŸ›‘οΈ ISO 45001🌿 IGBC AP

Audits that cut your energy bills and de-risk your facility.

"Save Earth, It Saves You."

BEE-certified energy, electrical-safety, fire-safety and power-quality audits for factories, warehouses and commercial buildings across Telangana & Andhra Pradesh β€” with ROI-ranked recommendations you can act on.

0+ Years Field Experience
β‚Ή90L+Annual Savings Identified
0+ Pumps Replaced (AgDSM)
10–30%Typical Savings per Audit

Is your Power Factor costing you?

Telangana DISCOMs bill on KVAh β€” poor PF is a silent surcharge on every unit.

PF 0.80 β†’ +25% bill

Poor ← Power Factor β†’ Unity (1.0)

βœ“ KVAh vs KWh billing reconciliation
βœ“ APFC & capacitor bank sizing
βœ“ Harmonics & voltage unbalance study
βœ“ KVARH penalty recovery plan
Trusted by teams at CBREMicronQualcommISBGMRSilicon LabsCushman & WakefieldMeenakshi GroupValueLabs
What we do

Nine services. One accountable expert.

Comprehensive audit and compliance services for factories, warehouses, commercial buildings and residential complexes β€” delivered and signed by a BEE-certified auditor & Chartered Engineer.

⚑

Energy Audit

Detailed consumption analysis per BEE guidelines & EC Act 2001. Equipment-level analysis, load profiling and DPR β€” typically unlocking 10–30% savings.

BEE CertifiedEC Act 2001DPRISO 50001
πŸ›‘οΈ

Safety Audit (ISO 45001)

HIRA, workplace safety compliance aligned with ISO 45001, Factories Act and OISD norms β€” including fire safety, emergency preparedness and PPE audits.

ISO 45001HIRAFactories ActOISD
πŸ”Œ

Power Quality & PF Audit

PF, harmonics, unbalance and reactive power assessment. APFC and capacitor bank design to reach unity PF and eliminate KVAh-billing penalties.

KVAh BillingAPFC DesignHarmonicsTSSPDCL
πŸ—οΈ

ECBC Compliance

Energy Conservation Building Code assessment covering envelope, HVAC, lighting and SHW. Mandatory for buildings >500 sqm in notified states.

ECBC 2017GRIHAIGBCBEE Star
🌍

ESG Advisory & Reporting

ESG baseline, materiality mapping and sustainability reports aligned with GRI, BRSR (SEBI) and CDP β€” by a NISM & CRISIL certified ESG analyst.

GRIBRSRCDPScope 1/2/3
πŸ”§

Electrical Safety Audit

HT/LT panels, transformers, earthing, switchgear and cabling inspected against IE Act, NBC and NFPA β€” with thermography and IR testing.

CEA 2023NBCThermographyEarthing
🏒

Technical Due Diligence

Pre-acquisition or pre-lease assessment of buildings and industrial facilities β€” structural, MEP and compliance status for investors and tenants.

Pre-acquisitionMEP AuditRERABanks/FIs
πŸ”„

HOTO Inspection

Handover/Takeover of buildings, MEP systems and facilities β€” compliant, documented, defect-noted condition with snag lists and verification.

Snag ListMEP VerificationCommissioning
πŸ“ˆ

Operational Performance

OEE, maintenance practice and utility system assessment β€” compressed air, cooling towers, boilers β€” benchmarked to industry best practice.

OEEUtilitiesBenchmarkingKaizen
Telangana & AP Electricity Regulations

KVAh billing makes poor Power Factor expensive. Every month.

TSSPDCL & TSNPDCL bill HT and LT industrial consumers on KVAh β€” not KWh. Every unit of reactive power is added to your bill, and low-PF consumers attract KVARH penalty charges on top.

1.0Target PF (Unity) per DISCOM norms
KVAhBilling basis for HT & LT industry
KVARHPenalty charges on low PF
10–20%Typical bill savings after correction
Power FactorKVA (100 KW load)Bill ImpactStatus
1.00 (Unity)100 KVABaseline β€” no penaltyβœ“ IDEAL
0.95105 KVA+5% higher billβœ“ GOOD
0.90111 KVA+11% higher bill⚠ ACCEPTABLE
0.85118 KVA+18% higher bill⚠ POOR
0.80125 KVA+25% + KVARH chargesβœ— VERY POOR
0.70 or below143+ KVA+43% + heavy penaltiesβœ— CRITICAL
Get a Power Quality Audit β†’
How we work

A transparent path from first call to verified savings.

Structured methodology, no surprises β€” and support that continues after the report is delivered.

Initial Consultation

Facility, utility bills and concerns understood. No-cost 30-minute call.

Data Collection

Bills, equipment lists, drawings, past reports and energy records.

Site Walkthrough

Inspection, measurements, PQ logging and photo documentation.

Analysis & DPR

Energy & cost analysis with ROI-ranked recommendations.

Report & Presentation

Findings presented to management with an implementation roadmap.

Implementation Support

Vendor guidance, supervision and post-implementation verification.

VRK

Venkateswara Rao Kammili

Managing Partner Β· Itihas Engineering Services

23+ years across energy management, facility operations and statutory compliance β€” earlier career with CBRE, JLL, Sodexo and Wipro Eco Energy, managing Fortune 500 pharma, telecom and IT facilities.

πŸ›οΈ IEI Member🏒 FTCCI Member🌿 IGBC APπŸ’Ό NSC Certified
About the expert

One auditor. Eight credentials. Zero hand-offs.

Every audit is performed and signed by a certified professional who has run the very facilities being audited β€” LEED Platinum operations, cyclone-recovery crisis response, and 3,500+ pump installations under India's AgDSM programme.

BEECertified Energy Auditor
CEng (IEI)Chartered Engineer
ISO 45001OH&S Certified Professional
IGBC APGreen Building Professional
ECBCCertified Professional
NISM-CRISILESG Risk Analyst
NSCElectrical & Office Safety
33 kVElectrical Supervisory Licence
Knowledge hub

Insights for Indian industry.

Practical guidance on energy efficiency, safety compliance and sustainability.

⚑ Telangana · Must read

KVAh Billing: Why Your Power Factor Determines Your Electricity Bill

A factory at PF 0.80 pays 25% more than one at unity β€” for the same work done. How APFC panels recover this cost.

🏭 Energy

Top 10 Energy Saving Opportunities in Manufacturing

Motors, compressed air, lighting, HVAC and furnaces are 75% of factory consumption. Where the 10–30% hides.

🌍 ESG

BRSR Reporting: What Listed Companies Must Disclose

SEBI's BRSR for the top 1000 listed companies β€” material topics, Scope 1/2/3 and supply-chain disclosures.

πŸ›‘οΈ Safety

ISO 45001 vs OHSAS 18001: Transition Roadmap

Worker participation, context of organisation and risk-opportunity thinking β€” a practical gap analysis.

πŸ”Œ Power Quality

Harmonics: the Hidden Cause of Failures & High Bills

VFDs and non-linear loads inject harmonics that overheat transformers and trip breakers. Diagnose before it costs.

πŸ—οΈ ECBC

ECBC 2017 Compliance: a Practical Checklist

Envelope U-values, HVAC COP, lighting LPD and SHW for buildings above 500 sqm β€” what builders need to know.

Get in touch

Request a quote or a free consultation.

No-obligation quote for your facility audit. We respond within 24 hours.

πŸ“ž
Phone / WhatsApp+91 98499 08842 Β· +91 91331 12302
πŸ“
Location

Kukatpally, Hyderabad, Telangana
Serving Pan-Telangana & Andhra Pradesh

⏰
Working Hours

Mon–Sat: 9:00 AM – 6:00 PM
Sunday: By appointment

Send an Enquiry

Opens WhatsApp with your enquiry pre-filled β€” fastest way to reach us.

πŸ’¬